Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9202330

- Product Categories
- Friendly Links
Information Name: | The railway special edition forklift meter |
Published: | 2012-11-09 |
Validity: | 90 |
Specifications: | No |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Product the the special railway forklift meter is suitable for the measurement of bulk materials in the field of railways, ports, docks, mines and other real-time loading, wagon overloading control and protection, as well as cargo management and trade settlement, etc., for strengthening the the loading operations management, to prevent overload and underload, to improve the efficiency and effectiveness of the loading and unloading operations, to ensure the safety of the vehicle transport effectiveness. The product attributes two-line multi-mode detection, accurate data, and high weighing accuracy. · No need to stop fighting, automatic weighing in the lifting process, does not affect the loading efficiency, prevent overload and underload. · Printable loading time, unit name, name of goods, weight, license plate number and other data. · 240 × 128mm large-screen displays, display weighing results, tired of heavy results, and system information. · Display and keyboard with backlight for easy night operation. · Automatic sound overload alarm, a timely reminder of the simple and direct. · Memory function, the shutdown of electronic scales, weighing stored data can be retained. Strong anti-jamming capability, suitable for a variety of operating environments. , Loaders electronic scales boot boot loader should be preceded by 5 to 10 times to do the warm-up upgrade, enhance boom, its purpose is to make the hydraulic oil pressure sensor to warm up to normal operating temperature, reducing oil temperature instability symmetrical weight accuracy. Second, in the weighing process, should be avoided loader driving after weighing any driving speed is not limited. Such as vehicles weighing in, the speed should be controlled below 5 km / h, but accuracy will be reduced by 0.5%. Third, in the weighing process, enhance the boom after position sensor enhance the speed should be as uniform as possible (to put an end to the plus / minus throttle or throttle pause). Loaders should try to choose than the level of the ground or on a slope of less than 15 ° to enhance weighing five after the completion of the weighing hoppers should fall to the lowest position, in order to prepare for the next shovel Liu said weight. The main features of weighing range: 0 to 10T? Accuracy class: ± 0.5-1% achieve international legal Metrology OIML Y (b) level accuracy class? Display division value: 10 kg, 20 kg, 50 kg,? Scale re: Automatic dynamic weighing? instrument protection class: IP61? working environment temperature: -25 ℃ to +50 ℃? Relative Humidity: 10% to 95% RH? system voltage: 12 ± 25% to 24 ± 25% instrument front-end with a regulated power supply, the operating voltage regulated power supply for 12 ± 25% to 36 ± 25%? instrument designed for the power of memory (RAM) battery, data can be stored for long periods? vibration level: IEC-60068 -2-27 (international standard)? clear the LCD display (112 × 64mm), (the color and intensity of the backlight) with adjustable backlight for easy night operation failure analysis process normally, take the paper when printing blank, no writing. a check ribbon is worn, aging, and the need to replace the ribbon. b, Check whether the ribbon is installed anti Replace positive. Normal, take the paper, but you can not print. Check that the instrument is set in a non-weighing state, non-weighing state can not print, press the [non-] key to switch the weighing status can be printed. 3, paper printing difficulties or printing errors. Check the printer dust is too much, the oil spill is too large, the need to clean or replace the printer the printer. 4, jam, check whether the printing paper is a paper Cao stuck. Other instructions Specifications: 1. Weighing operation before you start the loader, and enhance the boom 5 to 10 times, do a warm-up to enhance the hydraulic oil pressure sensor to warm up to normal operating temperature. 2 in the weighing operation, when the tipper shovel on the material is ready to enhance first controls the movable arm of the lever must be placed on the pole in position, i.e. the dump body is in its final position. 3. The electronic scales loader requirements strictly boom system lubrication, the friction of the boom system has a direct impact on the electronic scales weighing accuracy. Loader should be weighing than the level of the ground. Transaction description of the the product payment method: pay 30% deposit installation commissioning is completed to pay the balance |
Admin>>>
You are the 10150 visitor
Copyright © GuangDong ICP No. 10089450, Zhengzhou Dacheng Weighing Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 10150 visitor
Copyright © GuangDong ICP No. 10089450, Zhengzhou Dacheng Weighing Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility